Published: Vol 17, Iss 1, Jan 5, 2027 DOI: 10.21769/BioProtoc.5916 Views: 12
Reviewed by: Harsimranjit SekhonAnonymous reviewer(s)
Abstract
Luciferase Activity Modulated by Phosphorylation (LAMP) is a genetically encoded bioluminescent biosensor platform that converts reversible protein phosphorylation into changes in NanoLuc luciferase activity. LAMP builds on NanoLuc Binary Technology (NanoBiT), in which low-affinity LgBiT and SmBiT fragments complement when brought into proximity by interacting proteins. In PKA LAMP, SmBiT is engineered with protein kinase A (PKA) phosphorylation sites and a protein phosphatase 2A (PP2A) recognition motif to generate PKABiT/pBiT. Phosphorylation inhibits LgBiT-pBiT complementation and decreases luminescence, whereas dephosphorylation restores complementation and increases luminescence. Here, we provide 96-well plate-reader protocols for implementing LAMP and its underlying NanoBiT complementation strategy in living cells. We describe empirical optimization of NanoBiT protein–protein interaction assays by comparing alternative N- and C-terminal reporter orientations. In contrast to NanoBiT interaction measurements, LAMP provides a robust kinetic readout in which stimulus-induced luminescence changes are normalized to each well’s own pre-treatment baseline. The modular cis and trans configurations established for LAMP provide a framework for coupling phosphorylation-sensitive complementation to protein interactions and signaling complexes. Together, these protocols provide sensitive, scalable approaches for measuring dynamic protein phosphorylation and protein interactions in living cells.
Key features
• LAMP adapts NanoBiT complementation to convert reversible protein phosphorylation into reciprocal changes in NanoLuc luminescence in living cells.
• PKA LAMP provides a kinetic, plate-reader-compatible readout of kinase/phosphatase signaling in which stimulus-induced luminescence changes are normalized to each well’s own pre-treatment baseline.
• Modular LAMP supports cis and trans configurations; PKA-binding and binding-deficient sensors assess PKA activity and A-kinase anchoring protein (AKAP)-mediated anchoring in living cells.
• The NanoBiT workflow compares N- and C-terminal reporter orientations and optionally normalizes protein–protein interaction (PPI) complementation to a HiBiT-defined maximal LgBiT response.
Keywords: A-kinase anchoring proteinsGraphical overview
NanoBiT complementation assay: NanoLuc luciferase is split into a small peptide (SmBiT) and a larger fragment (LgBiT), both being fused to two proteins of interest (POIs). Interaction of the fusion partners brings SmBiT and LgBiT into proximity and reconstitutes NanoLuc activity, producing luminescence as a readout of protein–protein interaction. Reporter orientation can strongly affect complementation and should therefore be optimized for each protein pair. LAMP assay: LAMP makes NanoBiT complementation sensitive to reversible phosphorylation. In the published PKA LAMP sensor, SmBiT is engineered with PKA phosphorylation sites and a protein phosphatase 2A (PP2A)/B56 recognition motif to generate PKABiT/pBiT. The cis sensor used in this protocol contains LgBiT and PKABiT on the same A-kinase anchoring protein (AKAP)-based polypeptide. Under basal conditions, complementation produces bright luminescence. Cyclic adenosine monophosphate (cAMP)-dependent activation of PKA phosphorylates PKABiT, inhibits complementation, and decreases luminescence; dephosphorylation has the opposite effect. LAMP can also be configured in trans, with LgBiT and pBiT attached to separate interacting proteins [1].
Background
Reversible protein phosphorylation is a ubiquitous regulatory mechanism controlled by the opposing activities of protein kinases and phosphatases. Genetically encoded kinase activity reporters permit real-time measurements of signaling in intact cells, but most established reporters rely on fluorescence and phosphorylation-dependent binding to phospho-amino-acid recognition domains. Many widely used kinase sensors incorporate forkhead-associated (FHA) domains, which preferentially bind phospho-Thr, whereas many Ser/Thr kinases, including protein kinase A (PKA), preferentially phosphorylate Ser [2–5]. Bioluminescent reporters offer a complementary approach with high sensitivity, low background, and no requirement for excitation light. NanoLuc luciferase is particularly well suited to this purpose because of its small size, high light output, and stability [6].
NanoLuc Binary Technology (NanoBiT) was developed to monitor protein–protein interactions (PPIs) in living cells [7]. NanoLuc is divided into LgBiT and the small, low-affinity SmBiT peptide. When these fragments are fused to interacting proteins, proximity promotes complementation and restores luciferase activity. Because SmBiT and LgBiT have low intrinsic affinity, complementation primarily reflects association of the fusion partners rather than reporter-driven binding. NanoBiT has been used in our studies of PKA and protein phosphatase 2A (PP2A) signaling complexes [8–10]. However, the geometry of the fusion proteins can strongly influence complementation, making empirical testing of N- versus C-terminal reporter placement and appropriate expression controls important for assay development.
We recently adapted NanoBiT to develop Luciferase Activity Modulated by Phosphorylation (LAMP), a bioluminescent biosensor platform for monitoring reversible protein phosphorylation in living cells [1]. Rather than using SmBiT solely as a passive proximity reporter, LAMP engineers the small NanoBiT component so that phosphorylation regulates its interaction with LgBiT. In the published PKA LAMP sensor, two PKA phosphorylation sites and a PP2A/B56 recognition motif were incorporated into SmBiT to generate PKABiT/pBiT. Phosphorylation inhibits LgBiT-pBiT complementation, likely through electrostatic and/or steric effects of the phosphate groups, whereas dephosphorylation restores complementation. This design produced an approximately sevenfold decrease in luminescence after PKA activation and an approximately sevenfold increase during dephosphorylation of a regeneratively phosphorylated sensor [1].
LAMP extends NanoLuc complementation from a measure of protein proximity to a reporter of enzymatic signaling. Replacing Thr with Ser in early PKA LAMP sensors substantially increased dynamic range, consistent with the Ser preference of PKA and many other Ser/Thr kinases [1,4,5]. The core LAMP sensor is small and modular: LgBiT and pBiT can be expressed in cis on the same polypeptide or in trans on separate interacting proteins [1]. For example, trans PKA LAMP demonstrated that PKA regulatory subunits RIα and RIβ form functional heterodimers in living cells, with activities indistinguishable from RIα and RIβ homodimers [1]. The published LAMP design can be adapted by modifying phosphorylation and dephosphorylation determinants and complements fluorescence-based biosensors.
The current protocol first describes empirical optimization of NanoBiT complementation for PPI measurements. Alternative placements of SmBiT and LgBiT at the N- or C-termini of interacting proteins can be compared in a 96-well plate-reader format. An optional feature is normalization of the NanoBiT PPI signal to maximal LgBiT complementation. After measuring SmBiT/LgBiT complementation, excess cell-permeable HiBiT peptide is added. Because HiBiT binds LgBiT with high affinity and outcompetes SmBiT, the resulting luminescence approximates a maximal response for the available LgBiT-tagged POI. Expressing the basal NanoBiT signal relative to this HiBiT-defined maximum provides a semi-quantitative means of accounting for differences in abundance and availability of the LgBiT fusion between conditions and for cell-density differences among technical replicates. A similar HiBiT-based normalization strategy has been described for NanoBiT measurements of RAS GTPase protein interactions [11]. The optimal NanoBiT orientation remains protein-pair dependent, so relevant configurations should be tested empirically rather than assuming that one fusion geometry will generalize. As an example, we compare the interaction of liprin-α1 with PP2A regulatory subunit B56δ, previously studied by coimmunoprecipitation [12], using a selected subset of reporter orientations (Figure 1). In this example, C-terminal SmBiT-tagged liprin-α1 paired with C-terminal LgBiT-tagged B56δ yields the highest light output. A liprin-α1 mutant that cannot interact with B56δ [12] serves as a negative control.
We then describe a 96-well plate-reader implementation of PKA LAMP. Unlike a NanoBiT PPI assay, LAMP does not depend on optimizing absolute complementation intensity because its principal output is the kinetic change in luminescence relative to each well’s own pre-treatment baseline. The protocol uses a published A-kinase anchoring protein LAMP sensor [1], which places LgBiT and PKABiT in cis on a scaffold based on small membrane AKAP (smAKAP), which selectively binds RI PKA regulatory subunits [13]. A nuclear exclusion sequence (NES) replaces smAKAP’s N-terminal plasma membrane-targeting sequence and confers cytosolic localization [1] (see Graphical overview). As an application, we compare signaling by wild-type (WT) PKA regulatory subunit RIβ and the R335W RIβ variant associated with Marbach-Schaaf neurodevelopmental syndrome [8,14]. Isoproterenol activates endogenous β-adrenergic receptor/cAMP signaling, and the resulting decrease in LAMP luminescence reports increased PKABiT phosphorylation. Comparison of the PKA-binding and binding-deficient (ΔPKA) sensors assesses the contribution of AKAP-mediated anchoring to the response (Figure 2).


Materials and reagents
Cell line
Potentially any cell line can be used for the NanoBiT complementation assay and the LAMP assay (see General note 2). We use HEK293 cells (ATCC, catalog number: CRL-1573) and Cos-1 cells (ATCC: CRL-1650) in this protocol.
Table 1. Plasmids used in this protocol
| Plasmid | Reference |
|---|---|
| pCMV PKA/RIβ-V5 sh5 WT | Pool et al. (2025) [8] |
| pCMV PKA/RIβ-V5 sh5 R335W | Pool et al. (2025) [8] |
| pEGFP-N1 2NES-AKAP-FLAG LgBiT-PKABiT27 (WT) | Kong and Strack (2025) [1] |
| pEGFP-N1 2NES-AKAP-FLAG L65,70P LgBiT-PKABiT27 (ΔPKA) | Kong and Strack (2025) [1] |
| pCMV LipA1-FLAG-SmBiT (Lipα-Sm) | unpublished |
| pCMV LipA1-FLAG-SmBiT m1,4,8 (Lipα*-Sm) | unpublished |
| pCMV LipA1-FLAG-V5-LgBiT (Lipα-Lg) | unpublished |
| pCMV B56delta-FLAG-SmBiT (B56δ-Sm) | unpublished |
| pCMV SmBiT-B56delta (Sm-B56δ) | unpublished |
| pCMV B56delta-FLAG-V5-LgBiT (B56δ-Lg) | unpublished |
Reagents
1. Isoproterenol (Sigma-Aldrich, catalog number: I5627-5G)
2. Hank’s balanced salt solution (HBSS) (GIBCO, catalog number: 14175-095)
3. Opti-MEM (GIBCO, catalog number: 31985-070)
4. High-glucose DMEM (GIBCO, catalog number: 11965-092)
5. Fetal bovine serum (FBS) (GIBCO, catalog number: 26140079)
6. Collagen Type I (rat tail, 3.25 mg/mL) (GIBCO, catalog number: 354236)
7. Lipofectamine 2000 (Invitrogen, catalog number: 11668019)
8. 1 M HEPES (GIBCO, catalog number: 15630-080)
9. 100× GlutaMax (GIBCO, catalog number: 35050-061)
10. Fluorofurimazine (FFz) (DC Chemicals, catalog number: DC74576)
11. Collagen Type I rat tail (Corning, catalog number: 354236)
12. Custom-made cell-permeable HiBiT peptide (RRRRRRRRRGVSGWRLFKKIS) (GenScript Biotech)
Note: N-terminal arginine (R) residues are not needed when cells are lysed in Triton X-100-containing buffer, as in this protocol.
13. Triton X-100 (Fisher BioReagents, catalog number: BP151-500)
14. Tris base (Research Products International, catalog number: T60040)
15. Ethanol, 95% (Decon Laboratories, catalog number: 2801)
16. Ethanol, 100% (Decon Laboratories, catalog number: 2716)
Solutions
1. Collagen-coating solution (see Recipes)
2. Cos medium (see Recipes)
3. 1/10th Cos medium (see Recipes)
4. HiBiT peptide solution (see Recipes)
5. Fluorofurimazine stock (see Recipes)
Recipes
1. Collagen-coating solution
| Reagent | Final concentration | Quantity or volume |
|---|---|---|
| Collagen Type I (from rat tail) | 1:100 (32.5 μg/mL) | 0.5 mL |
| 30% ethanol | n/a | 49.5 mL |
2. Cos medium
| Reagent | Final concentration | Quantity or volume |
|---|---|---|
| DMEM | n/a | 500 mL |
| Heat-inactivated FBS | 10% | 55.6 mL |
| 100× GlutaMax | 1 mM | 5.56 mL |
| Total | n/a | 561.16 mL |
Heat-inactivate thawed FBS at 55 °C for 30 min. Heat-inactivated FBS can be stored at -20 °C and thawed in a water bath before Cos medium preparation. Filter-sterilize and warm the Cos medium in a water bath before use.
3. 1/10th Cos medium
| Reagent | Final concentration | Quantity or volume |
|---|---|---|
| DMEM | n/a | 4.445 mL |
| Cos medium | n/a | 0.49 mL |
| 1 M HEPES | 10 mM | 50 μL |
| 100× GlutaMax | 1 mM | 44 μL |
| Total | 5 mL |
4. HiBiT peptide solution
| Reagent | Final concentration | Quantity or volume |
|---|---|---|
| 1/10th Cos medium | n/a | 1.079 mL |
| 10% Triton | 1% | 120 μL |
| 20 mg/mL HiBiT peptide | 12 μg/mL | 0.72 μL |
| Total | 1.2 mL (10 μL/well) |
5. Fluorofurimazine stock
| Reagent | Final concentration | Quantity or volume |
|---|---|---|
| 100% ethanol | n/a | 1.0 mL |
| Fluorofurimazine powder | 25 mM | 10.81 mg |
Store at -20 to -80 °C in an opaque tube or wrapped in aluminum foil.
Laboratory supplies
1. 100 mm tissue culture dishes (e.g., Sarstedt, catalog number: 83.3902, or similar)
2. 5 mL serological pipettes (e.g., Fisherbrand, catalog number: 13-678-11D, or similar)
3. 10 mL serological pipettes (e.g., Fisherbrand, catalog number: 13-678-11E, or similar)
4. 25 mL serological pipettes (e.g., Fisherbrand, catalog number: 13-678-11, or similar)
5. 96-well plates, white, clear flat bottom, sterile (e.g., Corning, catalog number: 3610, or similar)
6. 15 mL conical tubes (e.g., Sarstedt, catalog number: 62.553.205, or similar)
7. 50 mL conical tubes (e.g., Sarstedt, catalog number: 62.547.100, or similar)
8. 500 mL filter unit with 0.2 μm PES membrane (e.g., Thermo Fisher, catalog number: 569-0020, or similar)
9. 1,000 μL pipette tips (e.g., Eppendorf Research Plus, catalog number: 3123000063, or similar)
10. 200 μL pipette tips (e.g., Eppendorf Research Plus, catalog number: 3123000055, or similar)
11. 10 μL pipette tips (e.g., Eppendorf Research Plus, catalog number: 3123000020, or similar)
12. 12-channel repeat pipettor (e.g., Eppendorf, catalog number: 4861000791, or similar)
13. Hemocytometer (e.g., Hausser Scientific Bright-Line, catalog number: 3110, or similar)
14. Single-channel repeat pipettor (e.g., Eppendorf, catalog number: 4987000134, or similar)
Equipment
1. 96-well plate reader (e.g., TECAN SPARK, BioTek, Molecular Devices)
Software and datasets
1. GraphPad Prism (GraphPad Software) or similar program for statistical analysis
2. Microsoft Excel or similar program for data entry and analysis
Procedure
A. Cell seeding
1. Coat the wells of 96-well white, clear-bottom plates with 1% collagen in 30% ethanol for 5 min at room temperature. Remove the collagen solution and let the wells dry completely (see General note 1). Then, UV-irradiate the plates for 5 min.
Note: White-walled plates are highly recommended over black-walled plates for luminescence measurements because they reflect light uniformly within each well and maximize signal intensity. Clear-walled plates are not recommended because light can pass between wells, reducing signal and increasing crosstalk from adjacent wells.
2. Seed the 96-well plates with 4 × 104 cells/well of HEK293 cells by dispensing 130 μL/well of 3 × 105 cells/mL cell suspension using a single-channel repeat pipettor for same-day transfection. For Cos-1 cells, we seed the 96-well plates with 6 × 104 cells/well by dispensing 130 μL/well of 4.65 × 105 cells/mL cell suspension for same-day transfection. If doing next-day transfection, the number of cells seeded per well can be reduced by half. In general, cells should be ~70% confluent at the time of transfection. Also, depending on the cell type, the collagen-coating step A1 may be omitted if cells are transfected the day after seeding (see General note 2).
Note: Even in properly humidified CO2 incubators, corner and edge wells of 96-well plates evaporate faster than wells in the center of the plate. This can result in loss of cells and outlier luminescence readings. Uneven evaporation is minimized by filling the spaces in between wells with 100–130 μL of sterile distilled H2O. To minimize loss of cells during aspiration, always aspirate the same spot in each well (e.g., 12 o’clock).
3. Place the 96-well plates in the 37 °C incubator until the cells are attached to the plates. Attachment should be verified by microscopy and can range from 1 h if plates are collagen-coated to >8 h if they are not.
B. Plasmid considerations
LgBiT and SmBiT cloning vectors are available from Promega. They include 16-residue-long Gly-Ser-rich linkers separating LgBiT/SmBiT from multiple cloning sites. These flexible linkers should be retained when transferring LgBiT/SmBiT cassettes to vectors expressing POIs. Whereas Promega vectors drive low-level SmBiT/LgBiT expression from the thymidine kinase promoter, we use the higher-expressing cytomegalovirus (CMV) promoter to extend the assay to hard-to-transfect cell lines and primary cells. We prefer to use restriction-enzyme-based subcloning strategies, in which LgBiT/SmBiT-linker cassettes are PCR-amplified using forward and reverse primers with unique restriction sites that allow for cloning between either N- or C-terminal epitope tags of plasmids expressing the POI from a CMV promoter. PCR amplicons and POI vectors are then digested with those restriction enzymes, ligated, and transformed into competent bacteria. Other subcloning methods (e.g., Gibson assembly, Golden Gate, Gateway) or whole cDNA synthesis may also be employed. cDNAs need to be verified by Sanger sequencing.
C. Transfection
1. Prepare 100 ng/μL DNA plasmid stocks in 10 mM Tris-HCl pH 8.0 buffer.
2. Transfection for the NanoBiT complementation assay: Prepare a 4 ng/μL DNA solution (diluted in Opti-MEM) with initially an equal mass ratio of plasmids expressing LgBiT and SmBiT fused to either the N- or C-terminus of two POIs (see Table 1). If the two POIs are substantially different in size, an excess of the plasmid expressing the larger POI should be transfected so that expression of the two POIs is similar. Because LgBiT/SmBiT complementation can produce luminescence bright enough to saturate the detector and noticeably deplete NanoLuc substrate, dilute the reporter plasmids 1:3 to 1:20 with an irrelevant CMV-driven expression vector (such as pmRuby-C1/N1 or pEGFP-C1/N1). Importantly, dilution with an “empty” vector not expressing a protein is less effective because it does not compete with translation of the reporter. For one fusion-protein pair, we transfect 6–8 wells as technical replicates.
Critical: The optimal SmBiT/LgBiT fusion configuration is protein-pair dependent. When biologically feasible, test the relevant N- and C-terminal configurations before conducting PPI experiments; all eight configurations [N/C(2) * SmBiT/LgBiT(2) * POIs(2)] need not be tested if structural or targeting constraints exclude particular fusions. For instance, N-terminal fusions need not be considered if a POI has a cleaved N-terminal targeting or signal sequence. Once suitable fusion combinations have been established, different LgBiT:SmBiT plasmid ratios can be tested to optimize the signal; complementation is generally favored when SmBiT- and LgBiT-tagged proteins are expressed at similar levels.
3. Transfection for the LAMP assay: Make a 4 ng/μL DNA plasmid solution (diluted in Opti-MEM) with a 4:1 to 8:1 mass ratio of protein of interest (for example, RIβ WT and R335W) to the reporter (for example, NES-AKAP-FLAG-LgBiT-PKABiT27 WT and NES-AKAP-FLAG-LgBiT-PKABiT27 ΔPKA; see Table 1). For the LAMP assay, select a condition that will act as a reference and prepare enough solution to transfect 16 wells. We use 8 wells (one column) as technical replicates for treatment with agonist (isoproterenol) and the other 8 wells as technical replicates for treatment with vehicle. For conditions that will only be treated with agonist, we transfect 8 wells as technical replicates.
4. Add an equal volume of 0.8% Lipofectamine 2000 in Opti-MEM solution to each 4 ng/μL DNA plasmid solution to prepare the transfection solution. For example, for 8 technical replicates, mixing 270 μL of Lipofectamine and DNA solutions for a total of 540 μL provides extra volume to account for pipetting inaccuracies. The concentrations in the transfection solution should be 2 ng/μL plasmid and 0.4% Lipofectamine 2000. Aspirate the wells of each 96-well plate and add 60 μL/well of transfection solution. Place the 96-well plates in a 37 °C incubator.
5. After 3–6 h of incubation, aspirate the transfection solution from the wells in the 96-well plates and add 130 μL of fresh Cos media to each well using a single-channel repeat pipettor. Return the 96-well plates to the 37 °C incubator.
D. NanoBiT complementation assay
1. Luminescence measurement
a. Approximately 36–48 h after transfection, aspirate wells of 96-well plates and add 50 μL/well of 1/10th Cos media containing 100 μM FFz substrate (from a 25 mM stock in ethanol) using a single-channel repeat pipettor (see General note 3).
b. Immediately place the 96-well plate into the plate reader and read the basal luminescence at 0, 5, and 10 min. We set up a protocol to read luminescence in 4–5 kinetic cycles with an integration time of 200 ms. Alternatively, set a continuous measurement of 20–30 kinetic cycles with the integration time set at 200 ms. The reading can be stopped when it reaches a plateau.
c. After basal luminescence measurements, add 10 μL/well of 12 μg/mL HiBiT peptide solution using a single-channel repeat pipettor. Mix by gently tapping the plate 2–3 times. HiBiT provides an optional estimate of maximal LgBiT complementation for normalization of relative LgBiT abundance/accessibility and cell-density differences among replicate wells.
d. Immediately read the entire 96-well plate every 5 min for 30 min after ~3 s shaking. For every luminescence reading, measure the luminescence in 4–5 kinetic cycles with an integration time of 200 ms. Alternatively, program continuous measurement of 40–60 kinetic cycles with an integration time of 200 ms. Readings can be stopped when a plateau is reached.
e. Once the measurement is complete, export both the basal and HiBiT data to an Excel spreadsheet for data analysis.
E. LAMP assay (example: β-adrenergic agonist-mediated PKA activation)
1. Serum starvation and luminescence measurement
a. Approximately 36–48 h after transfection, aspirate wells of 96-well plates and add 50 μL/well of Opti-MEM using a single-channel repeat pipettor to initiate serum starvation, which lowers basal cAMP concentration and PKA activity. Place 96-well plates in the 37 °C incubator.
b. Approximately 4–6 h following addition of Opti-MEM, add 5 μL/well of 225 μM FFz in Opti-MEM (from a 25 mM stock in ethanol; final concentration of FFz is 20.5 μM) to the 96-well plates using a single-channel repeat pipettor. Incubate the plates at room temperature for 5 min.
Note: Keep the 25 mM FFz ethanol stock protected from light and return to the freezer immediately.
c. Place the 96-well plate into the 96-well plate reader. Read the basal luminescence across five kinetic cycles with integration time set at 200–400 ms.
d. While the plate reader is reading the basal luminescence, prepare a 12× stock (1.2 μM) isoproterenol. Fill each tip of a 12-channel repeat pipettor with ≥60 μL of the 1.2 μM isoproterenol or Opti-MEM (vehicle) and program the pipettor to dispense 8 steps of solution at 5 μL/step. Filling is best done from a row of wells in a 96-well plate. The final concentration of isoproterenol in each well should be 100 nM following agonist addition. This dose elicits maximum β-adrenergic receptor-mediated PKA activation in HEK293 cells.
Critical: Agonist preparation and addition are time-sensitive because isoproterenol is unstable in solution. Dissolve isoproterenol-HCl within 5 min of addition to cells and keep it cold and protected from light. Prepare a 10 mM stock in HBSS (-Ca2+, -Mg2+; e.g., 2.48 mg/mL) and make the final 1.2 μM dilution while baseline luminescence is being recorded.
e. When the basal luminescence read is complete, use the 12-channel repeat pipettor to add 5 μL/well of 1.2 μM isoproterenol solution to the 96-well plate promptly, starting at row A and moving down row-by-row in ~2 s intervals. This addition interval approximates the top-to-bottom read interval of a TECAN Spark at an integration time of 200 ms and may have to be adjusted for other plate readers and integration times. Importantly, arranging technical replicates in columns minimizes systematic (between conditions) errors. Timed addition protocols can capture subtle kinetic differences in the activation of membrane-bound, cytosolic, and nuclear PKA by isoproterenol (Figure 2 in [1]).
f. Return the 96-well plate to the plate reader, shake the plate for 3 s, and immediately read the luminescence across 40–60 kinetic cycles with integration time set at 200 ms.
g. Once the method protocol is complete, export the data to an Excel spreadsheet and save the file for data analysis.
Data analysis
1. For NanoBiT complementation analysis, basal NanoBiT luminescence can optionally be normalized to the maximal HiBiT/LgBiT response to a) correct for cell density differences in replicate wells and to b) account semi-quantitatively for differences in abundance and availability of the LgBiT-tagged POI between conditions.
a. For each technical replicate, plot the repeated basal NanoBiT measurements and the subsequent HiBiT measurements as a function of time. Select a consistent plateau or peak value from each phase for normalization; apply the same rule to all conditions within an experiment.
b. Basal luminescence reports proximity-dependent complementation between the LgBiT- and SmBiT-fusion proteins. Following addition of excess HiBiT peptide, high-affinity HiBiT/LgBiT complementation provides an estimate of the maximal response of the available LgBiT-tagged POI. Divide the selected basal NanoBiT value by the corresponding HiBiT value for each replicate when this normalization is used.
c. Compare basal NanoBiT signals, or basal/HiBiT ratios when HiBiT normalization is used, among the fusion orientations tested. Higher normalized complementation is consistent with more efficient proximity-dependent NanoBiT reconstitution, but differences can also reflect fusion geometry; therefore, interpret the ratio as a semi-quantitative assay-optimization metric rather than a direct measurement of binding affinity (see Figure 1).
2. Analysis of LAMP assay data proceeds as follows:
a. Program the plate reader such that each complete plate read (96 values) is output in one time-stamped row. Matching addition- and read-intervals (see step E1e) is critical for this to be accurate, because plate readers typically do not time-stamp individual reads. Baseline reads and reads after agonist addition are separated by the time it takes to add agonists to wells (~20 s) and the delay between retraction of the plate, shaking, and initiation of reading (~30 s). This delay needs to be factored in if initial response kinetics are to be quantified. An Excel spreadsheet with raw TECAN Spark output, Excel templates for formatting, presentation, and analysis of the same data with GraphPad Prism, as well as step-by-step instructions for use of the templates are included as Supplementary information. Steps 2b–e below outline data analysis generalized for any plate reader.
b. Normalize each well to its own pre-treatment baseline. Average the luminescence values acquired before agonist addition and divide each value in the kinetic trace by this average. Express the result as a fraction of baseline (baseline = 1) or percent baseline luminescence (baseline = 100%). Plot the normalized traces as a function of time. For PKA LAMP, a decrease from baseline after isoproterenol treatment reflects increased PKABiT/pBiT phosphorylation.
c. Optional correction for baseline drift: If appreciable time-dependent drift is observed in the absence of agonist, include matched vehicle/no-agonist wells. Normalize these wells to their own pre-treatment baselines in the same manner as the agonist-treated wells, then correct the experimental traces for the corresponding vehicle trace. This correction accounts for agonist-independent changes in NanoLuc signal, including NanoLuc substrate depletion or decay. Apply the same correction method to all conditions within an experiment and report whether drift correction was used.
d. Quantify the LAMP response using a parameter appropriate for the experiment, such as the maximum change from baseline (fold or %), initial response rate (maximum of first derivative), or area under the curve. Because LAMP is a kinetic, within-well assay, absolute basal luminescence does not need to be optimized as long as the signal remains within the linear range of the detector and is sufficient to resolve the stimulus-induced change.
e. Optional normalization to a reference condition: When comparing enzyme variants, scaffolds, or other experimental conditions, express the selected LAMP response parameter relative to a biologically appropriate reference measured in the same experiment. For example, the response of a disease-associated PKA variant can be normalized to the corresponding WT enzyme. Report this as the LAMP response relative to reference, because the luminescence response is not calibrated to absolute catalytic activity. In the example shown in Figure 2, responses of PKA RIβ R335W are compared with WT RIβ, and responses obtained with the PKA-binding NES-AKAP-LAMP sensor can be compared with the PKA-binding-deficient NES-AKAP-LAMP ΔPKA that reports on unbound PKA activity [1,8].
Validation of protocol
The current protocol described for the NanoBiT complementation assay is an optimized version of our previously described NanoBiT live-cell protein interaction assay, which has been used and validated in the following research articles:
Sandal et al. [9]. De novo missense variants in the PP2A regulatory subunit PPP2R2B in a neurodevelopmental syndrome: potential links to mitochondrial dynamics and spinocerebellar ataxias. Hum Mol Genet (Figure 1).
Pool et al. [8]. Aberrant phase separation of two PKA RIβ neurological disorder mutants leads to mechanistically distinct signaling deficits. Cell Rep (Supplemental Figure 5F, H, and L).
Wu et al. [10]. Extended regulation interface coupled to the allosteric network and disease mutations in the PP2A-B56δ holoenzyme. Proc Natl Acad Sci USA (Figure 4 and Extended Data Figure 10).
The PKA LAMP procedure is based on and was validated in the following research article, which describes cis and trans LAMP configurations and their applications to PKA and PP2A signaling. The trans configuration was used to demonstrate functional RIα/RIβ heterodimerization, whereas cis sensors were used for compartmentalized PKA measurements and a regeneratively phosphorylated sensor for PP2A/B56δ signaling.
Kong and Strack [1]. Ultrasensitive bioluminescent reporters of protein kinase A based on luciferase activity modulated by phosphorylation (PKA LAMP). J Biol Chem 301(8):110445.
General notes and troubleshooting
General notes
1. We coat 96-well plates with collagen for same-day transfection to accelerate cell attachment. For next-day transfection, collagen coating is not required. Other coating substrates may be appropriate depending on the cell type.
2. This protocol uses Cos-1 and HEK293 cells, but other cell types, including HeLa cells, neuronal cultures, and MCF-7 cells, can also be used. Seeding density, coating, transfection conditions, and reagents should be adapted to the cell type.
3. The NanoBiT complementation protocol uses FFz substrate in 1/10th Cos media. We have also used Nano-Glo Live Cell Substrate (Promega, catalog number: N2012), which gives comparable results but is more expensive. Other assay buffers, such as Opti-MEM or the Nano-Glo LCS dilution buffer, may also be used.
Troubleshooting
Problem 1: Too low or too high luminescence signal in NanoBiT complementation assay.
Possible causes: The selected NanoBiT fusion orientation produces insufficient complementation, or reporter expression is too low or too high for the dynamic range of the plate reader.
Solutions: Compare alternative N- and C-terminal reporter orientations and titrate reporter expression as needed. In this protocol, reporter plasmids are diluted 1:3 to 1:20 with an irrelevant expression vector. Use a known interacting pair or previously validated orientation as a positive control when possible. Avoid interpreting absolute luminescence alone as interaction strength; use HiBiT normalization when appropriate and include suitable negative controls.
Problem 2: LAMP luminescence is too high or saturates the detector.
Possible cause: Absolute reporter luminescence exceeds the linear range of the detector. This is an instrumentation/expression issue rather than a requirement to optimize LAMP complementation.
Solution: Reduce detector gain and/or reporter plasmid input while maintaining the experimental plasmid ratios. Because LAMP is analyzed as a kinetic change from each well’s own baseline, the goal is simply to keep the signal within the detector’s linear range while retaining sufficient signal-to-noise to resolve the response. A neutral-density or semi-transparent film can be used only when instrument settings and reduced reporter input are insufficient.
Problem 3: LAMP luminescence is low, or the kinetic response has poor signal-to-noise.
Possible causes: Low LAMP reporter expression, inadequate NanoLuc substrate, or plate-reader settings that provide insufficient signal-to-noise.
Solutions: Confirm reporter expression, substrate preparation, and plate-reader settings. If necessary, increase reporter plasmid input while maintaining the experimental plasmid ratios. LAMP does not require empirical optimization of N- versus C-terminal complementation geometry; the relevant criterion is whether basal signal is sufficient to resolve the stimulus-induced change from baseline.
Problem 4: No LAMP response after cAMP mobilization.
Possible cause: Isoproterenol may have lost potency because of prolonged storage in solution or exposure to oxygen, light, heat, or unfavorable pH.
Solution: Dissolve isoproterenol-HCl in HBSS and make the final dilution less than 5 min before agonist addition. Prepare fresh solution for each plate and keep it cold and protected from light.
Problem 5: LAMP baseline luminescence drifts over time.
Possible cause: Time-dependent changes in NanoLuc signal, including depletion or degradation of luciferase substrate.
Solutions: 1) Minimize unnecessary exposure of FFz to light. 2) Dilute LAMP sensor plasmid further with an irrelevant expression plasmid (e.g., pEGFP). 3) If baseline drift is still appreciable over the experimental time course, include matched vehicle/no-agonist wells and use them for optional drift correction as described in the LAMP Data Analysis section. Vehicle controls are not required when baseline luminescence is stable.
Supplementary information
The following supporting material can be downloaded in this ZIP file containing:
1. PKCb-pBiT + PMA (raw output).xlsx: TECAN Spark output of typical LAMP experiment
2. Analysis of PKCb-pBiT + PMA.xlsx: Normalized and formatted data for GraphPad Prism
3. Analysis of LAMP template (col1=veh).xlsx: Analysis template with drift correction by column 1
4. PKCb-pBiT + PMA graphs.prism: Prism file visualizing data from the experiment
5. 5-60 LAMP (Spark method).xml: TECAN Spark method used (import to use)
6. LAMP Analysis Protocol.docx: Description of experiment and step-by-step instructions
Acknowledgments
Funding: NIH R21 AG080472-01, the Ataxia Charlevoix-Saguenay Foundation, Regents of the University of California, A22-2853-S004 (Jordan’s Guardian Angels), DoD/CDMRP (AR230307), the Eagles Autism Foundation, and the Simons Foundation Autism Research Initiative (SFARI).
This protocol was described and validated in Kong and Strack [1]. Previous work from which the protocol was developed includes [8–10].
Author contributions
Conceptualization, S.S.; Investigation, C.J., A.G.P.G.M., S.S.; Writing and Editing, C.J., A.G.P.G.M., S.S.; Funding acquisition, S.S.; Supervision, S.S.
Competing interests
The authors declare no competing interests.
References
Article Information
Publication history
Received: Oct 2, 2026
Accepted: Nov 16, 2026
Available online: Nov 26, 2026
Published: Jan 5, 2027
Copyright
© 2027 The Author(s); This is an open access article under the CC BY-NC license (https://creativecommons.org/licenses/by-nc/4.0/).